Products

Facebook
Product Name : Pressure Compensator Type
Pressure Compensator Piston Pump

 

    Enlargement

    Q'ty :

     

    Model Numbers Geometry
    Displacement
    cm3/rev (cu.in/rev)
    Minimum
    Adj.Flow
    cm3/rev (cu.in/rev)
    Operation Pres.
    MPa(PSI)
    Shaft Speed Range
    r/min
    Approx.Mass
    kg(lbs.)
    Rated※2 Intermittent※1 Max. Min. Flange Mtg. Foot
    Mtg.
    A10-
    FR01B-12*
    10.0(.610) 2 (.122) 16(2320) 21(3050) 1800 600 5.1(11.2)
    A10-FR01C/H-12* 8.5(18.7)
    A16-
    *-R-01-*-*-K-32
    15.8(.964) 4 (.244) 16(2320) 21(3050) 1800 600 16.5(36.4) 18.7(42.1)
    A22
    -*-R-01-*-*-K-32
    22.2(1.355) 6 (.366) 16(2320) 21(3050) 1800 600 16.5(36.4) 18.7(42.1)
    A37
    -*-R-01-*-*-K-32
    36.9(2.25) 10 (.610) 16(2320) 21(3050) 1800 600 28.0(61.7) 32.3(71.2)
    A56
    -*-R-01-*-*-K-32
    56.2(3.43) 12 (.732) 16(2320) 21(3050) 1800 600 35.0(77.2) 39.3(86.7)
    ※1.Whenener setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.

    ※2.Care should be taken in cases of used ay a higher pressure than the rated pressure, because operating terms may be restricted. For example, if used as per maximum illustrated operating conditions, intermittent time at maximum flow is restricted to under 1/5 of one cycle time and under 6 seconds simultaneously. Conditions may vary according to the actual working pressure and delivery.
    proimages/piston-pumps/a_96.gif
    A16 -F -R -01 -B -S -K -20
    Series Number Mounting Direction of
    Rotation
    Control
    Type
    Pres. Adj. Range
    MPa(PSI)
    Port
    Position
    Shaft Extension Design Number
    A16
    (15.8 cm3/rev)
    F:
    Flange Mtg.

    L:
    Foot Mtg.
    (Viewed
    From shaft
    end)
    R:
    Clockwise
    (Normal)※1
    01:
    Pressure Compensator
    Type
    B:1.2-7(170-1020)
    C:1.2-16(290-2330)
    H:1.2-21(170-3050)
    None:
    Axial Port※2

    S:
    Side Port
    K:
    Keyed
    shaft
    32
    A22
    (22.2 cm3/rev)
    B:1.2-7(170-1020)
    C:1.2-16(290-2330)
    32
    A37
    (36.9 cm3/rev)
    B:1.2-7(170-1020)
    C:1.2-16(290-2330)
    H:1.2-21(170-3050)
    32
    A56
    (56.2 cm3/rev)
    32
    ※1.Available to supply pump anti-clockwise rotation.

    ※2.The axail ports is not available to the N.American Design Standard of A37 and A56.
    proimages/piston-pumps/ar_char_3.gif Type ”A 16” Viscosity 20mm2/s (100 SSU) [ISO VG32 Oils, 50oC (122oF)]
    -Performance Characteristic Curve
    proimages/piston-pumps/a16_char_6.jpg
    -Input power
    proimages/piston-pumps/a16_char_9.jpg
    proimages/piston-pumps/ar_char_3.gif Type ”A 22” Viscosity 20mm2/s (100 SSU) [ISO VG32 Oils, 50oC (122oF)]
    -Performance Characteristic Curve
    proimages/piston-pumps/a22_char_6.jpg
    -Input power
    proimages/piston-pumps/a22_char_9.jpg
    proimages/piston-pumps/ar_char_3.gif Type ”A 37” Viscosity 20mm2/s (100 SSU) [ISO VG32 Oils, 50oC (122oF)]
    -Performance Characteristic Curve
    proimages/piston-pumps/a37_char_6.jpg
    -Input power
    proimages/piston-pumps/a37_char_9.jpg
    proimages/piston-pumps/ar_char_3.gif Type ”A 56” Viscosity 20mm2/s (100 SSU) [ISO VG32 Oils, 50oC (122oF)]
    -Performance Characteristic Curve
    proimages/piston-pumps/a56_char_6.jpg
    -Input power
    proimages/piston-pumps/a56_char_9.jpg
    Model Numbers Geometry
    Displacement
    cm3/rev (cu.in/rev)
    Minimum
    Adj.Flow
    cm3/rev (cu.in/rev)
    Operation Pres.
    MPa(PSI)
    Shaft Speed Range
    r/min
    Approx.Mass
    kg(lbs.)
    Rated※2 Intermittent※1 Max. Min. Flange Mtg. Foot
    Mtg.
    A10-
    FR01B-12*
    10.0(.610) 2 (.122) 16(2320) 21(3050) 1800 600 5.1(11.2)
    A10-FR01C/H-12* 8.5(18.7)
    A16-
    *-R-01-*-*-K-32
    15.8(.964) 4 (.244) 16(2320) 21(3050) 1800 600 16.5(36.4) 18.7(42.1)
    A22
    -*-R-01-*-*-K-32
    22.2(1.355) 6 (.366) 16(2320) 21(3050) 1800 600 16.5(36.4) 18.7(42.1)
    A37
    -*-R-01-*-*-K-32
    36.9(2.25) 10 (.610) 16(2320) 21(3050) 1800 600 28.0(61.7) 32.3(71.2)
    A56
    -*-R-01-*-*-K-32
    56.2(3.43) 12 (.732) 16(2320) 21(3050) 1800 600 35.0(77.2) 39.3(86.7)
    ※1.Whenener setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.

    ※2.Care should be taken in cases of used ay a higher pressure than the rated pressure, because operating terms may be restricted. For example, if used as per maximum illustrated operating conditions, intermittent time at maximum flow is restricted to under 1/5 of one cycle time and under 6 seconds simultaneously. Conditions may vary according to the actual working pressure and delivery.