Product Name : DSG-01-50 Directional Valve
DSG-01-50 Directional Valves

 

    Enlargement

    Q'ty :

     

    Model Mumbers Max. Flow
    L/min
    (U.S.GPM)
    Max Operating Pres.
    MPa(PSI)
    Max. T-Line Back Pres.
    MPa(PSI)
    Max. Changeover
    Frequency min
    (Cy cles /Min)
    MPa(PSI)
    Approx. Mass
    kg(Ibs)
    DSG-01-3C*-*-50 63(16.6) 31.5(4570)
    Spool Type 60 Only
    25(3630)
    16(2320) 300
    R Type Sol. Only
    120
    2.2
    DSG-01-2D*-*-50
    DSG-01-2B*-*-50 1.6
    proimages/Directional_Valves/title_92.gif Graphic Symbols proimages/Directional_Valves/title_97.gif
    Besides the use of the standard 2-position valves aforementioned in the :List of Standard Models and Maximum Flow" ,the 3-position valves also can be used as the 2-position valves using the two of their three positions. In this case, there are two kinds of the valve available. One is the valve using the neutral position and SOL a position (2B*A) and another is the valve using the neutral position and SOL b position(2B*B).
    proimages/Directional_Valves/pe_1_96.gif
    REVERSE MOUNTING OF SOLENOID
    In spring offset type, it is a standard configuration that the solenoid is mounted onto the valve in the SOL b position(side). However, in this particular spool-spring arrangement, the mounting of the solenoid onto the valve in the reverse is as shown below. As for the valve type 2B*A and 2B*B, please refer to the explanatino under the heading of "Valve Using Neutral Position and Side Position" given below.
    proimages/Directional_Valves/pe_1_97.gif
    Series Mumber Valve Size NO. of Valve Position Spool-Spring Arrangment Spool Type Special Two Position Valve Coil Type Electrical Conduit Connection Design Number
    DSG -01 -2 B 2 A -A220 -10 -50
    Solenoid Operated Directional Valve 01 3:Three Positions

    2:Two Positions
    C:Spring Centered 2、3、4、9、10、11、12、40、60 - - AC:
    A110,
    A220,
    A240

    DC:
    D12,
    D24

    AC→DC:
    R110,
    R220
    10:
    Terminal
    Box Type


    20:
    Plug-in
    Connector
    Type
    50
    D:No-Spring 2
    B:Spring Offset 2、3、8 A
    B
    proimages/Directional_Valves/ar_char_3.gif LIST OF STANDARD MODELS AND THE MAXIMUM FLOW
    Models with AC Solenoids: DSG-01-***-A*
    proimages/Directional_Valves/pe_1_char_6.gif


    proimages/Directional_Valves/ar_char_3.gif VALVES USING NEUTRAL POSITION AND SIDE POSITION
    Models with DC or R Type Solenoids: DSG-01-***-D*/R*
    proimages/Directional_Valves/pe_1_char_7.gif
    Model Mumbers Max. Flow
    L/min
    (U.S.GPM)
    Max Operating Pres.
    MPa(PSI)
    Max. T-Line Back Pres.
    MPa(PSI)
    Max. Changeover
    Frequency min
    (Cy cles /Min)
    MPa(PSI)
    Approx. Mass
    kg(Ibs)
    DSG-01-3C*-*-50 63(16.6) 31.5(4570)
    Spool Type 60 Only
    25(3630)
    16(2320) 300
    R Type Sol. Only
    120
    2.2
    DSG-01-2D*-*-50
    DSG-01-2B*-*-50 1.6