Products

Facebook
Product Name : DSG-03 Directional Control Valve
DSG-03 Directional Valves

 

    Enlargement

    Q'ty :

     

    Model Mumbers Max. Flow
    L/min
    (U.S.GPM)
    Max Operating Pres.
    MPa(PSI)
    Max. T-Line Back Pres.
    MPa(PSI)
    Max. Changeover
    Frequency min
    (Cy cles /Min)
    MPa(PSI)
    Approx. Mass
    kg(Ibs)
    AC DC
    DSG-03-3C*-*-50 120(31.7) 31.5(4570)
    (Spool Type 60 Only
    25(3630))
    16(2320) 240
    (R Type Sol. Only 120)
    3.6
    (7.9)
    2.9
    (6.4)
    DSG-03-2B*-*-50 2.9
    (6.4)
    3.6
    (7.9)
    Besides the use of the standard 2-position valves aforementioned in the :List of Standard Models and Maximum Flow" ,the 3-position valves also can be used as the 2-position valves using the two of their three positions. In this case, there are two kinds of the valve available. One is the valve using the neutral position and SOL a position (2B*A) and another is the valve using the neutral position and SOL b position(2B*B).
    proimages/Directional_Valves/pe_6_96.gif
    REVERSE MOUNTING OF SOLENOID
    In spring offset type, it is a standard configuration that the solenoid is mounted onto the valve in the SOL b position(side). However, in this particular spool-spring arrangement, the mounting of the solenoid onto the valve in the reverse is as shown below. As for the valve type 2B*A and 2B*B, please refer to the explanatino under the heading of "Valve Using Neutral Position and Side Position" given below.
    proimages/Directional_Valves/pe_6_97.gif
    Series Mumber Valve Size NO. of Valve Position Spool-Spring Arrangment Spool Type Special Two Position Valve Coil Type Electrical Conduit Connection Design Number
    DSG -03 -2 B 2 A -A220 -10 -50
    Solenoid Operated Directional Valve 03 3:Three Positions

    2:Two Positions
    C:Spring Centered 2、3、4、5、9、10、11、12、40、60 - - AC:
    A110,
    A220,
    A240

    DC:
    D12,
    D24
    10:
    Terminal
    Box Type


    20:
    Plug-in
    Connector
    Type
    50
    D:No-Spring 2
    B:Spring Offset 2、3、8 A
    B
    proimages/Directional_Valves/ar_char_3.gif LIST OF STANDARD MODELS AND THE MAXIMUM FLOW
    Models with AC Solenoids: DSG-03-***-A*
    proimages/Directional_Valves/pe_6_char_6.gif


    proimages/Directional_Valves/ar_char_3.gif VALVES USING NEUTRAL POSITION AND SIDE POSITION
    Models with DC Solenoids: DSG-03-***-D*
    proimages/Directional_Valves/pe_6_char_7.gif
    Model Mumbers Max. Flow
    L/min
    (U.S.GPM)
    Max Operating Pres.
    MPa(PSI)
    Max. T-Line Back Pres.
    MPa(PSI)
    Max. Changeover
    Frequency min
    (Cy cles /Min)
    MPa(PSI)
    Approx. Mass
    kg(Ibs)
    AC DC
    DSG-03-3C*-*-50 120(31.7) 31.5(4570)
    (Spool Type 60 Only
    25(3630))
    16(2320) 240
    (R Type Sol. Only 120)
    3.6
    (7.9)
    2.9
    (6.4)
    DSG-03-2B*-*-50 2.9
    (6.4)
    3.6
    (7.9)