Product Name : COUNTERBALANCE MODULAR VALVES
Counterbalance Modular Valves 02

 

    Enlargement

    Q'ty :

     

    Model Mumbers Max Operating Pressure
    kgf/cm(MPa)
    Max. Flow L/min Mass kg
    MHA-03-*
    MHB-03-*
    MHP-03-*
    250(25) 80 3.5
    proimages/Modular_Valves/pf_2c_96.gif
    Series Mumber Valve Size Pres. Adj Range
    kgf/cm(MPa)
    MHP -03 -B
    MHA: Counterbalance Valve for A-Line
    MHB: Counterbalance Valve for B-Line
    MHP: Counterbalance Valve for P-Line
    03 M:2.5-8.5 (0.25-0.85)
    A:8.5-35 (0.85-3.5)
    C:35-140 (3.5-14)
    Instructions
    1.The minimum adjustment pressure equals the valve obtained from the minimum adjustment pressure
       characteristics plus the tank link back pressure of the next page. This back pressure should include
       the value of the T-line pressure drap characteristics of the valves stacked to the base plate side of the
       modular valve.
    2.To make pressure adjustment, loosen the lock unt and turn the pressure adjustment screw clockwise or
       anticlockwise. For an increase of pressure, turn the screw clockwise. Be sure to re-tighten the lock nut
       firmly after making adjustment to the pressure.
    Model Mumbers Max Operating Pressure
    kgf/cm(MPa)
    Max. Flow L/min Mass kg
    MHA-03-*
    MHB-03-*
    MHP-03-*
    250(25) 80 3.5