PRODUCTS

Home > Products > Electro-hydraulic Controls > E SERIES Relief Valves

E SERIES Relief Valves

Model Numbers
Description
EBG-03 EBG-06 EBG-10
Max. Operating Pres.
MPa (PSI)
24.5 (3350) 24.5 (3350) 24.5 (3350)
Max. Flow
L/min (U.S.GPM)
100 (26.4) 200 (52.8) 400 (106)
Min. Flow
L/min (U.S.GPM)
3 (.79) 3 (.79) 3 (.79)
Pressure Adjustment
Range Kgf/cm(PSI)
Refer to Model Number Designation
Rated Current C: 770 mA C: 750 mA C: 730 mA
H: 820 mA H: 800 mA H: 780 mA
Coil Resistance 10Ω 10Ω 10Ω
Hystersis Less than 3% Less than 3% Less than 3%
Repeatability Less than 1% Less than 1% Less than 1%
Weight
kg (lbs.)
5.6 (12.3) 6.3 (13.9) 10 (22)

























1.EBG valve pressure is steady with low noise.
2.Good for general traditional and micro-computer control to reach the best function of unifying hydraulic electronic.
3.Hi-precision easy micro-adjusting small pressure shift monmentry exciting pressure.
EB G -03 -C -T 50
Series Number Type of Mounting Valve
Size
Pres. Adj. Range
MPa (PSI)
Safety
Valve
Design
Number
EB:
Proportional
Electro-Hydraulic
Relief Valve
G:
Sub-plate
Mounting
03 C:-15.7 (-2275)

H:-24.5 (-3550)
None:
with Safety

T:
Without Safety Valve
50
06
10
 Input Current vs. Pressure
 Min. Adjustment Pressure
 Instructions
-Safety Valve
The pressure of the safety valve for EBG-03 is present at the value equat to the upper limit of the pressure adjustment range plus 2 MPa (290PSI) subject to a flow rate of 50 L/min (13.2 U.S.GPM).
The smae for EBG-06 is preset at the value equal to the upper limit of the pressure adjustment range plus 3.5 MPa(510 PSI) subject to a flow rate of 100 L/min (26.4 U.S.GPM).
The same for EBG-10 is preset at the value equal to the upper limit of the pressure adjustment range plus 4 MPa(580 PSI) subject to a flow rate of 200 L/min (52.8 U.S.GPM).
In case where the upper limit of operating pressure is low or the upper limit of flow rate to be used is different from the specified maximum flow,please adjust and determine the seting pressure of the safety valve at the value calculated from the following formula.
-Calculated From the followimg formula.
Setting pressure = (Operating pressure upper limit) + (Additional pressure indicated blow)
Taiwan Products, B2BChinaSources, B2BManufactures