Model nember designation |
 |
| Series Mumber |
Valve Size |
Pres. Adj Range kgf/cm(MPa) |
| MHP |
-03 |
-B |
MHA: Counterbalance Valve for A-Line
MHB: Counterbalance Valve for B-Line MHP: Counterbalance Valve for P-Line |
03 |
M:2.5-8.5 (0.25-0.85)
A:8.5-35 (0.85-3.5) C:35-140 (3.5-14) |
|
Instructions
1.The minimum adjustment pressure equals the valve obtained from the minimum adjustment pressure
characteristics plus the tank link back pressure of the next page. This back pressure should include
the value of the T-line pressure drap characteristics of the valves stacked to the base plate side of the
modular valve.
2.To make pressure adjustment, loosen the lock unt and turn the pressure adjustment screw clockwise or
anticlockwise. For an increase of pressure, turn the screw clockwise. Be sure to re-tighten the lock nut
firmly after making adjustment to the pressure.